What does an Owner want with BIM?

Posted on 11:53 by Unknown
Question: What does an owner want from BIM?
Answer: Essentially, the same thing they wanted from CAD.

In reality, the answer is actually another question.

Who is the owner?

When people talk about the owner and what they want and what they need, it always varies, because they all seem to be speaking about different stakeholders.


This list breaking down each type of owner is from the perspective of *my* company. If there are other owners who would like to chime in, please feel free to comment. Add some areas that I've missed or tell me how each of these different stakeholders functions in your company.

Owner Breakdown: 


Project Manager: Oversees the bidding, budget, implementation and communication of construction projects. May have been an architect in a past life. Balances a lot of pressures from company leadership, finance and occupants and manages supports (such as walk-throughs from occupants and facilities staff, to space numbering for CAFM and signage for wayfinding).
Needs: Timely documentation to keep all design, review, occupant, support and construction personnel on the same page.
Wants: Anything that will reduce RFI's and help keep the project on-time and on-budget.

Occupant: Will be working in the space. The only one who knows how their workflow should and could happen. Also, one major part of 'owner' that does not have a background in design, construction or engineering.
Needs: A space that will operate as needed for the foreseeable future. A pretty rendering, probably delivered on paper in a project meeting, that helps reassure them that's what they are getting.
Wants: A space that will operate as needed for the foreseeable future, but, may not always be able to communicate precisely what that is, or what it will cost.

Finance: Is petitioned for projects by occupants and project managers and facilities staff and various support services, and balances the needs of the many over the long-term.
Needs: An accurate estimate of scope and price. A pretty rendering, probably delivered in powerpoint, that tries to make a renovation look as tempting to fund as the purchase of fancy Radiology equipment that will actually generate revenue directly.
Wants: Precision and documentation.
(other stakeholders such as the legal department and administrative boards would fall under the same basic description)

Real Estate: Manages space. Ensures that all departments are functioning and accessible in locations with adequate resources to perform their primary duties. Manages departmental moves, from simple to complex, and takes care of leases (whether we are leasing to others, or renting space for our departments).
Needs: Scope of proposed projects, accurate inventory of existing functions and their supplies.
Wants: Scope and schedule to stay as close as possible, so that the shuffleboard game of freeing up spaces for future projects can continue.

This section of the list is often what is referenced by the designers I network with. They are not technical gurus when it comes to Revit MEP or AutoCAD or CAFM or CMMS. They are the ones that wield the most power or get the most facetime with Architects and GC's, though.

Facilities Sub-Breakdown: 


Maintenance Staff: Repairs breaks, performs preventative maintenance to ensure maximum up-time and equipment and systems functioning long beyond their original design specs. In smaller hospitals, this will be a generally educated maintenance staff, in larger facilities, this will be broken down according to skilled craft (Building Finishes/Carpentry, HVAC/R, Plumbing, Electrical, Major Mechanical, Plant).
Needs: Accurate documentation that will help them perform their work as quickly as possible to minimize damage, or the downtime of a revenue-producing department, or future infection concerns for patients, visitors and staff.
Wants: Want the information to be where it says. Looking for a shut-off valve, the zones on a floor need to be called out on the plans. Looking for a section or detail mark and then getting to the details page and realizing there is no corresponding details means that a room gets taken out of service and holes get cut into walls or ceiling tiles get popped out, again causing infection control concerns.
Older staff prefer to look at paper drawings, younger staff expect electronic access to cut down on constant running back and forth across a large campus.

Operations Administration: Schedules preventative maintenance tasks to ensure uptime on all systems and long-term system performance. Sets baselines for all equipment and tracks maintenance history for a myriad of uses. Takes information from new projects and inserts it into a Computerized Maintenance Management System (CMMS) and/or a Computerized Aided-Facilities Management (CAFM) system. This history helps the Engineers or Facility Managers to make the best specifications (with regard to expected performance and reliable materials and brands).
Needs: Accurate documentation.
Wants: Something which is as simple as possible to import into programs like Maximo and Archibus.

Engineering Staff / Facility Manager: Sets material and equipment specifications, reviews proposed projects during the design phase, tours construction sites during construction, commissions buildings prior to occupancy, uses long years of experience to spot problems (as well as deviations from specified materials or necessary system redundancies).
When new projects do not perform as expected, these are the folks who trouble-shoot the systems and tweak/retrofit them until they perform as needed. They also oversee projects such as system upgrades (happening outside of renovations) and major equipment replacements (such as chillers, air handling units, major pumps and utility loops).
Needs: Accurate documentation that is easy to access and simple to read.
Wants: They don't really care how they get their information (paper, PDF, DWG, RVT), so long as they have it when they need it, and they like the option to carry it out to the site.

CAD / BIM Management Coordination: Sometimes, this role is held by a facility manager or engineer, but, larger companies will have an archivist of some sort.
This person sets the CAD/BIM Standards for the new construction and any special projects that occur. Their first involvement in a construction project is during closeout when they review documents for electronic deliverables compliance. When files are rejected for being sloppy or incomplete, noob designers at other companies protest to their project managers that the owners are idiots who don't know what they need, then this Coordinator attends a meeting with their project manager and eventually convinces the other design monkey that they do, in fact, know quite a bit about CAD/BIM and the long-term needs of their facility (because this is such a great and productive way to spend one's time).
They take in new data, archive it as a project, then patchwork the MEPFP system information into a working set of drawings for ease of use by the engineers, mechanics/skilled maintenance personnel and future renovation and planning needs.
This role manages the technology transitions, such as paper to CAD and CAD to BIM or plotting stations to tablet computers, as transparently as possible for the end users and any random stakeholders.
This person, of practicality and necessity, cares more about basic drawing neatness and clarity than about superficial things like fonts and dimension styles.
Needs: Accurate and EDITABLE documents that can be kept alive and updated throughout the life of a building (in many cases, over 100 years) in formats that they have the ability to work with. In our case, this is DWG or RVT.
Wants: Neatness, clarity, progress.

We also have other support services (Information Systems, Telecommunications, Key Control, Security, Clinical Engineering, etc) that might need to use our CAD/BIM files as they plan and maintain their systems across the campus and across the rest of the healthcare system. These other stakeholders are generally not of concern to the design and construction contractors, as they will get their information directly from the Facilities staff.
Read More
Posted in AMEP, Applications, BIM, CAFM, Database, Engineering, Facilities Management, Revit, RMEP | No comments

Wednesday, 22 August 2012

BIM and FM people, new Labs Project

Posted on 07:01 by Unknown
I hope you facilities management types out there, that are keeping an eye out for such things, have noticed the new project from Autodesk Labs.

They're currently testing an application which provides a link between Maximo and Revit (for those non-FM people, IBM Maximo is a CMMS, or a computerized maintenance management system, aka, work orders).

You can get download and test here. If you can try it out, be sure to provide feedback, that's what they want and need to see if they can make this a viable product.

From the Labs site:

Richly attributed data about building assets, that are developed in Revit during the building design and construction phases, can be published directly into Maximo during commissioning or at building "handover," thus supporting more immediate and efficient use of Maximo once the building is occupied. The Revit asset data can be exported in the COBie data specification, if desired. In addition, the BIM/3D asset data can be viewed inside Maximo, in context with Maximo applications and processes.
The technology preview consists of an add-in to Revit 2013 and integrated visualization of Autodesk® BIM 360 Glue™ viewer inside Maximo Version 7.1 or newer.

Autodesk® BIM 360™ Glue is a data-centric, cloud-based management solution for building and infrastructure projects that provides easier access to project models and data to support collaborative, multidisciplinary workflows across authoring tools and project control applications. It enhances cross-team coordination globally as updates are made more quickly available in project models. For more information about BIM 360 Glue, please go to www.autodesk.com/bim360

Download an introductory video here. 

My facility has not yet upgraded to Maximo, but, I hope we'll be able to get it done soon.

Read More
Posted in | No comments

Thursday, 12 July 2012

AUGI 2012 Salary Survey is Revamped!

Posted on 10:40 by Unknown

As promised last year, I decided to take a fresh look at the AUGI Salary Survey this time around. The questions hadn't changed much from the original format I inherited when I started with the 3rd survey, so the whole thing was pretty much scrapped, and we've started with a clean slate.
I appreciate all of the input from fellow AUGI members, as well as my instructors and professors at SLU.

This year's survey consists of 24 questions, roughly broken down into four areas:
Your demographic
Your role
Your company demographic
Your industry's state

As always, this is an anonymous survey. I am the only one who will ever have access to the database of individual entries, the answers cannot be tied back to you or your company in any way, and the information will only be reported in broad groups.

I did bring back some popular questions that will enable us to trend back for a couple of years. But, there will also be some new questions to help focus on the state of our industries.

Did you receive an increase or decrease in pay? Are you thinking about leaving your job? If so, why?
What market does your company serve or how do they specialize? Has your workload increased or decreased this year? Has your outsourcing increased or decreased this year? Have you let subscriptions lapse or purchased new software and hardware? What percentage of your projects are BIM, and, if you are doing BIM, why? Is cloud computing a go or no-go? How did you find your current role, through networking or advertising?

The AUGI Annual Salary Survey is about so much more than just salaries.
BUT! Of course, we all need to participate in order to have data from which we can draw valid conclusions about which industries are performing the best, which have the happiest and most secure employees and so much more.

Application Engineers, Programmers, Architects, Designers, Managers and Coordinators (CAD/BIM/Project, etc), Drafters, Trainers, Interns, etc... speak and be heard!

The survey ends August 4th, get your answers in now and see the results in the September 2012 issue of AUGIWorld Magazine!!! 


(wordle mashup of markets served and specialties)
Read More
Posted in AUGI, AUGIWorld Magazine, BIM, CAD/Design Salary Survey | No comments

Wednesday, 2 May 2012

Autodesk Facility Management Suite 2013

Posted on 11:42 by Unknown
IF Autodesk delivered a Facility Management Suite (which they do not), here is what should be in it.


Facility Management Suite - Standard

AutoCAD MEP
Revit MEP
Raster Design
Image Modeler
Vault

For the Premium Suite, add Showcase and Constructware
For the Ultimate Suite, throw in Green Building Studio

Yes, I know what a couple of you are thinking. You're wondering why I did not include Navisworks (or Adobe Acrobat Viewer) on my list.
Navisworks Freedom is not a Facilities Management (CAFM) tool, and Navisworks Manage has some great features, but, they are extreme overkill for day to day operational needs.

If some have found uses for Navisworks post-construction, in the built environment, that is great! But, in the opinion of someone who has been working in the Facilities Engineering department of a six million square foot medical center (where any given space is renovated once every thirteen years, but, maintained every day) for well over a decade, I declare that it is not a viable approach long-term.

See this conversation on the AUGI forums for thoughts and ideas from both sides of the fence:
http://forums.augi.com/showthread.php?117785-Linking-Data-Spreadsheet-to-Navisworks-for-Facility-Management

We take in data from various construction projects. We archive the project, then work the MEPFP components into a patchwork quilt which we work off of. If we make one-off changes in-house, those will be drawn up and changed on our documents (using AutoCAD MEP or Revit MEP). We then distribute bits and pieces of this information to architects, engineers and general contractors who work on the 50-75 construction projects we have going on around our campus at any given time.
Since we are over 100 years old now, we do have a vast library of scanned blueprints spanning a century of new construction and renovations. Raster Design would be a fabulous addition to our toolset, filling in gaps in our more current electronic records.
With so much information in our archives (that might need to be accessed at any random time), and with such a geographically scattered work team, a good data management solution is in order.
 In their spare time, our staff engineers attempt to find ways to modernize our buildings and reduce our energy consumption. Once they identify projects, they must sell them to our executives in order to compete for the scant funding available.

Well, now that I have shared what should be in an Autodesk Product Suite geared toward the Facilities customer, I will be serious for a moment and let you know that I will soon have the opportunity to post a review of the AutoCAD Design Suite, if you'd like the chance to read about something that actually is for sale.
Read More
Posted in Applications, CAFM, Facilities Management, funny | No comments

Thursday, 15 March 2012

Medical Facility Moves from AutoCAD to BIM

Posted on 11:34 by Unknown
This is the first article in a series, documenting the process that a multi-million square foot hospital went through to make the big move from 2d to 3d.

Moving from AutoCAD to BIM for Building Floor Plans – The Wexner Medical Center at The Ohio State University’s BIM Implementation Project

By Joe Porostosky, Senior Manager of Facilities Information and Technology Services at The Ohio State University

The Wexner Medical Center at The Ohio State University is reaching the end of  a project to convert all of our buildings from 2D AutoCAD drawings to 3D Building Information Models.  This project covers 53 buildings and slightly more than six million square feet.  Over the next five blog posts, my colleague, Brian Skripac, and I will share how the project was initiated, how it was executed, and the impact it has had on the Medical Center.

At that time, we identified the following as the immediate benefits of the implementation:

    High quality 3D visualizations
    Energy analysis and modeling
    Improved planning in the areas of space, operations, security, and others
    Improved drawing accuracy via field verification and further use of as-built documentation
    Time savings in updating to the BIM model following construction or renovation projects versus AutoCAD
    Utilizing industry standard drawing standards
    Improved communication with leadership and customers as it relates to space usage and layout

I encourage you to read the entire article. I'll try to remember to comment and link when the next installments are posted.
Read More
Posted in Autocad, BIM, CAFM, Facilities Management | No comments

Saturday, 25 February 2012

What version of AutoCAD are you currently using?

Posted on 13:19 by Unknown
This month AUGI is running a poll on the homepage, there are still a few more days left to take part, so please go to www.augi.com and cast your vote.

The survey is over on the right-hand column, below the Quick Links.

You can see the results of last month's poll in HotNews.
Please feel free to chime in, no matter what flavor of AutoCAD you're using... vanilla, LT, electrical, mechanical, architecture, mep...

Please pick the primary version you/your company is currently using. We'd really like to know.

I'll be adding a little bit of commentary on the article with the numeric results, and I'd love to quote you! Please add a comment below (or shoot me an email) with a quick reason for the version you are using. For example:

We're using 2012 (MEP) because we only have 3 seats in-house and work with a lot of outside files, so it is just simpler to keep on the current release. - Melanie Perry, facilities management

We're using 2005 (vanilla) because we use an add-on software that hasn't been updated to work on a newer version of AutoCAD. - Joe Schmoe, ABC HVAC

Thank you for your participation!
Read More
Posted in Applications, AUGI, Autocad | No comments

Wednesday, 18 January 2012

OT: Blackout Day

Posted on 05:51 by Unknown

http://en.wikipedia.org/wiki/Wikipedia:SOPA_initiative/Learn_more

https://www.google.com/landing/takeaction/

http://www.cadablog.blogspot.com/2012/01/my-take-on-sopapipa.html

http://www.blog.cadnauseam.com/2012/01/18/dark-times-dark-sites/

And, of course, being as this blog focuses a lot on Autodesk software, here's a pointed statement reminding folks that, despite their appearance on crowdsourced lists, Autodesk does not, in fact, support SOPA.

http://autodesk.blogs.com/between_the_lines/2012/01/autodesk-does-not-support-sopa.html

Read More
Posted in Education, off-topic | No comments
Newer Posts Older Posts Home
Subscribe to: Posts (Atom)

Popular Posts

  • Busca usted las respuestas a sus preguntas acerca de AutoCAD
    Busca usted las respuestas a sus preguntas acerca de AutoCAD, la Personalización, Revit u otros productos de Autodesk en su propio idioma? E...
  • Revit + 3dsMax: Utilizing Render Techniques - A Winning Combination
    It's been too long since I've had a guest post, so, I'd like for you to enjoy this rendering tutorial. I met Ryan on www.forums...
  • Mtext Line Spacing
    From AutoCAD Help: If you enter ‑mtext (precede with hyphen) at the Command prompt, MTEXT bypasses the In-Place Text Editor and displays a...
  • St. Louis Metro Storm Update
    Well, just felt like making another update about the storm. It's so odd that we're here in our nice powered home but so many things ...
  • MAP tool of the day - ADERSHEET (rubbersheet)
    from MAP3D 2006 help: ADERSHEET (Rubber Sheet command) Performs rubber sheeting on selected objects Rubber sheeting is a nonuniform adjustme...
  • All my tech support genius
    I have said it time and again, only slightly tongue-in-cheek, that all of my most appreciated 'genius' moves are attributed to these...
  • VTENABLE and my new Scanner (mfp) is here!
    VTENABLE system variable (from autocad help) Controls when smooth view transitions are used. Smooth view transitions can be on or off for pa...
  • Autodesk MAP 3D 2007 Service Pack 1 Available
    Service Pack 1 has come out for MAP 2007 . I must admit that I was waiting for this before I installed. I'll post here like I did last y...
  • Very Valuable Variable: REMEMBERFOLDERS
    From the autocad help files: REMEMBERFOLDERS - Controls the default path displayed in standard file selection dialog boxes. 0 Restores the ...
  • 2006 System Variables D-L
    Continuing from yesterday's posts, From the help files... 2006 system variables beginning with the letters 'D' through 'L...

Categories

  • ACA
  • Alternative Energy
  • AMEP
  • Applications
  • AU2006
  • AU2007
  • AU2008
  • AUGI
  • AUGIWorld Magazine
  • Autocad
  • AutoCAD
  • Autodesk University
  • BIM
  • cad camp
  • CAD Camp
  • CAD/Design Salary Survey
  • CAFM
  • Database
  • Education
  • Engineering
  • Facilities Management
  • FMDesktop
  • funny
  • GatewayAUG
  • Hardware
  • HotNews
  • Job Opening
  • Media
  • off-topic
  • Revit
  • RMEP
  • St. Louis
  • Tutorials
  • Women In Design
  • Writing

Blog Archive

  • ▼  2013 (27)
    • ▼  November (3)
      • All my tech support genius
      • Uni: The end of the story
      • Revit + 3dsMax: Utilizing Render Techniques - A Wi...
    • ►  September (1)
    • ►  July (1)
    • ►  June (16)
    • ►  May (2)
    • ►  April (1)
    • ►  March (2)
    • ►  February (1)
  • ►  2012 (14)
    • ►  December (2)
    • ►  November (4)
    • ►  September (1)
    • ►  August (1)
    • ►  July (1)
    • ►  May (1)
    • ►  March (1)
    • ►  February (1)
    • ►  January (2)
  • ►  2011 (22)
    • ►  November (3)
    • ►  October (3)
    • ►  September (3)
    • ►  August (2)
    • ►  July (1)
    • ►  May (7)
    • ►  April (1)
    • ►  March (2)
  • ►  2010 (16)
    • ►  December (2)
    • ►  November (5)
    • ►  September (1)
    • ►  August (1)
    • ►  July (2)
    • ►  April (1)
    • ►  March (1)
    • ►  February (2)
    • ►  January (1)
  • ►  2009 (15)
    • ►  October (1)
    • ►  July (1)
    • ►  June (4)
    • ►  April (2)
    • ►  February (7)
  • ►  2008 (58)
    • ►  December (1)
    • ►  November (1)
    • ►  October (1)
    • ►  September (3)
    • ►  August (4)
    • ►  July (7)
    • ►  June (4)
    • ►  May (5)
    • ►  April (4)
    • ►  March (10)
    • ►  February (9)
    • ►  January (9)
  • ►  2007 (69)
    • ►  December (7)
    • ►  November (9)
    • ►  October (6)
    • ►  September (3)
    • ►  August (1)
    • ►  July (5)
    • ►  June (4)
    • ►  May (4)
    • ►  April (3)
    • ►  March (9)
    • ►  February (11)
    • ►  January (7)
  • ►  2006 (121)
    • ►  December (7)
    • ►  November (8)
    • ►  October (10)
    • ►  September (13)
    • ►  August (16)
    • ►  July (14)
    • ►  June (14)
    • ►  May (6)
    • ►  April (7)
    • ►  March (7)
    • ►  February (14)
    • ►  January (5)
  • ►  2005 (68)
    • ►  December (9)
    • ►  November (10)
    • ►  October (7)
    • ►  September (4)
    • ►  August (5)
    • ►  July (11)
    • ►  June (9)
    • ►  May (4)
    • ►  April (9)
Powered by Blogger.

About Me

Unknown
View my complete profile